3004 aluminum plate API 650 flat-bottom oil storage tanks

Under the same sealing effect, the internal API 650 flat-bottom oil storage tanks floating roof API 650 tank can further reduce the evaporation loss compared with the external floating roof API 650 tank. This is due to the shielding of the fixed roof and the gas phase layer between the fixed roof and the inner floating plate, which has more significant heat insulation effect than the double disc floating roof of the API 650 flat-bottom oil storage tanks external floating roof tank.

Anti corrosion of API 650 flat-bottom oil storage tanks:
After using for a certain period of time, it is necessary to check the corrosion protection of the API 650 flat-bottom oil storage tanks. If necessary, the outer wall of the metal oil tank should be painted with new anti-corrosion paint to ensure that the outer wall of the API 650 flat-bottom oil storage tanks does not fall off and has good waterproof and rust resistance.
API 650 flat-bottom oil storage tanks cleaning:
The long-term use of API 650 flat-bottom oil storage tanks will produce impurities on the tank wall and deposit on the tank bottom, resulting in tank corrosion to leakage. According to the safety standard of oil tank, the API 650 flat-bottom oil storage tanks shall be cleaned and derusted regularly to ensure the quality of oil stored and the safety of oil tank equipment.

API 650 flat-bottom oil storage tanks Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.

Every after-sales service shall have a detailed record of the customer's product problems and handling methods. The records shall be sorted into volumes and filed on a monthly basis, and submitted to the technical department for filing. The problems found in the after-sales service shall be summarized in a timely manner, discussed with the technical department, the quality inspection department and the production department, and a proper solution shall be proposed for the technical department to improve in a timely manner;

"Efficiency is benefit, time is money", the company is equipped with a high standard logistics team. After the products pass the factory inspection, they will coordinate the shipment as soon as possible according to customer requirements and schedules to hand over the booked steel materials to customers at the first time, to ensure no delay of customer's project progress, to strive for more project preparation time for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!