Aboveground API 650 mechanically-anchored flat-bottom tanks
The bottom plate of the vertical API 650 mechanically-anchored flat-bottom tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API 650 mechanically-anchored flat-bottom tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.
Inspection of Welded storage tanks Surfaces Exposed during FabricationThe edges of API 650 mechanically-anchored flat-bottom tanks plates, openings and fittings exposed during fabrication shall be inspected carefully to make sure that any defects have been uncovered, as well as to determine that the work has been performed properly.Minor defects found may be repaired only after the inspector approves the method and extent of repairs. Materials that have more than minor defects that cannot be satisfactorily repaired shall be rejected.Spot radiographic or ultrasonic examination shall be not less than 6 in. extending along the weld. Spot radiography shall comply with the standards given in 7.15.1.3. Where spot radiographic or ultrasonic examination is applied at joint intersections, the surface shall be prepared and examined for a distance of 3 in. on each side of the intersection, making the minimum length of examination 6 in. on the horizontal weld and 3 in. on the vertical weld.
API 650 tanks in which liquid fluids are stored and designed to withstand atmospheric pressure operation, less than 18 kPa, or internal pressures not exceeding the weight of the API 650 mechanically-anchored flat-bottom tanks roof, with temperatures no higher than 93, 3 C are included in the scope of this design code.
Team concept: respect, communication, coordination and symbiosisBusiness philosophy: leading by strategy, driving by innovation, creating valueManagement concept: goal oriented, efficient operation, stimulation of vitality and continuous improvementQuality concept: standard guidance, control process, craftsman spirit, leading serviceTalent concept: lifelong learning, give full scope to the talents, the sea refuses no riverInnovation concept: innovation is the first driving force for the company's high-quality developmentCustomer concept: taking customers as the center is the foundation of the company's survival and development
Since its establishment, the company has participated in several key railway and highway projects. After years of development, the company’s API 650 mechanically-anchored flat-bottom tanks domestic market has been exported to more than a dozen provinces and cities including Kunming, Shenzhen, Hunan, Sichuan, Shanghai, Nanjing, Heihe, Jilin, Inner Mongolia, and Xinjiang . International trade is exported to Kazakhstan, South Korea, Vietnam, South Africa and many other countries, and has been well received by customers.