API standard 650 self-anchored tank snow load
The tank 20-in. inside-diameter nozzle shown in Figure F-6 is located in solid plate in the sidewall of a cylindrical storage tank 148 ft in diameter in an area where the thickness of the wall plate, tw, is 11/2 in. A corrosion allowance of 0.10 in. is required on all surfaces of the tank exposed to the stored liquid. The total internal pressure, Pl + Pg, at the center of the opening is 24.9 lbf/in.2 gauge. The thickness of the API standard 650 self-anchored tank wall plate, t, required by 5.10.3 for the latitudinal unit forces, T2, acting at this level is 1.44 in.API 650 tank has the advantages of less load on the floating plate, simple and light structure, and can save the central drainage pipe and rotating floating ladder on the API standard 650 self-anchored tank floating plate. The materials for easy construction and maintenance and sealing parts can avoid aging due to sunlight.Good news: The largest steel importer in Nigeria ordered 4068 tons API 5L X52Q PSL2 3LPE seamless pipes and also ordered 8 pcs 42699.6 m³big diameter Crude oil storage doom roof tank in A537CL2 steel grade. In Sep 2019, This Nigeria client visited our company and factory, they were very satisfied with our company's quality control,production capacity and service. We also have reached a agreement for Phase II Project, It is also with another 10,000 tons APl 5L X52Q PSL2 3LPE seamless pipes.Generally, external environment corrosion should be considered before design and construction of API standard 650 self-anchored tank and so on storage tanks. The corrosion on the outer surface of storage tank is often worse than that on the inner surface. Especially in the chemical industry area, there are often acid fog, alkali or salt dust in the atmosphere. These impurities form an active corrosive medium with dew or steam and oxygen in the atmosphere. The corrosion of the external environment of the storage tank shortens the maintenance period of the storage tank, even causes the storage tank to be scrapped in advance, which affects the normal operation of the storage and transportation.When providing technical services on site, the after-sales personnel shall strictly abide by the safety rules and regulations of the construction site, consciously take safety protection measures (such as wearing safety helmet when entering the construction site), accept the supervision and management of the site; without permission on the construction site, they shall not dismantle, smear or damage any goods; the commissioning of contract goods shall be carried out under the supervision of the site supervisor If necessary, it shall be approved by the site supervisor or the person in charge of the project department.
Latest NewsMore+