5083 aluminum plate API 650 anchored tanks
Our after sales department is an very important part of our department structures. After the customer receive steel materials, our after sales department will follow up regularly and solve problems for them in time if they have the needs. We romise to return the goods for free for its lifetime if it is quality of the steel material itself. Meanwhile, if you have any advice or complaints, also welcome to feed back to our after sales department, and we are trying to give better service to you.
Prefabrication requirements of API 650 anchored tanks, large vertical storage tank wall panels:1. The prefabrication of wall panel shall be processed in strict accordance with the requirements of the drawings, and inspection records shall be made.2. After the wall panel is rolled, it should be placed on the platform for inspection with a template. In the vertical direction, use a straight-line template to check, the gap should not be greater than 2 mm, and in the horizontal direction, use an arc-shaped template to check, and the interval should not be greater than 4 mm.3. When wall panels are rounded, attention should be paid to prevent irreversible plastic deformation caused by external forces. After rolling, it should be placed on the platform for inspection, and then placed on the prepared mold.
All API 650 anchored tanks fillet welds shall consist of a minimum of two passes. The ends of the fillet welds shall be 2 in. from the rat hole, and these welds shall be deposited by starting 2 in. from the rat hole and welding away from the rat hole. An acceptable alternative to stopping fillet welds 2 in. short of the rat hole would be to weld continuously through the rat hole from one side of the stiffener to the opposite side. All craters in fillet welds shall be repaired by back welding.