API Std 650 welded tanks for oil storage supports for stiffening rings
Investigation of SubgradeOn actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.
API standard 650, Welded Tanks for Oil Storage, Thirteenth Edition, has been published to ensure the safety, sustainability, and environmental performance of API Std 650 welded tanks for oil storage oil storage tanks. The updated standard will help continue operational excellence and trust between operators and manufacturers.
Tunisia cutomer purchased around 1500 tons 304L,310S stainless steel plate from us and make tanks in August, 2017. The company was skilled in the design and manufacture of stainless steel tanks, API Std 650 welded tanks for oil storage processing systems and equipment for the food, dairy, beverage, chemical, pharmaceutical, biotechnology, and pure water industries. They also sent the inspection team come our company and visited our production line. After using our stainless steel plate, the customer was very satisfied with our products.
}The bottom plate of the vertical API Std 650 welded tanks for oil storage directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API Std 650 welded tanks for oil storage, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.
Through the operation and management, brand advantage and improve pre-sales, sale of after-sales service, the efforts of the company into the industry leading enterprises.Relying on perfect quality management system, it has built up competition predominance and provided high quality, favorable price and perfect after service for customers.