API Std 650 flat-bottom tanks joints

Design of a Double-wall Tank
The outer bottom, shell, and roof of a double-wall tank shall enclose an insulating space around the bottom, shell, and roof or insulation deck of the inner tank that contains the stored liquid. The annular space shall be maintained at a low positive pressure, which necessitates that the enclosure be vapor-tight. The Purchaser shall specify the design metal temperature and pressure of the inner tank and may specify the design temperature and pressure of the outer tank API Std 650 flat-bottom tanks. The Purchaser shall state the specific gravity of the content to be stored, roof live loads, wind load, earthquake load where applicable, and corrosion allowance, if any.API 650 petroleum storage tank body design is mainly the design of tank bottom, API Std 650 flat-bottom tanks tank top and tank wall, and the design of tank wall is particularly important. As the main pressure bearing part of API 650 petroleum storage tank, the tank wall bears loads including liquid pressure, wind pressure, seismic load, opening stress, etc. The calculation of such loads is explained in detail in various API Std 650 flat-bottom tanks storage tank design standards. But in addition, the API 650 petroleum storage tank wall also bears the push-pull force and torque of the connected pipeline.Myanmar 4800 tons ABS AH36 and ABS A shipbuilding plates. This is very good customer of us, and we have cooperated many times for shipbuilding plates API Std 650 flat-bottom tanks . The most frequently ordered is shipbuilding plates, almost hundreds tons every 2 month, which are finally supplied to Myanmar’s navy. Just in last year, we have supplier more than 4800 tons shipbuilding plates for the customer continuously.The seal of floating roof API Std 650 flat-bottom tanks is a device used to reduce the evaporation loss of the storage liquid in the annular space between the tank wall and the outer ring plate of the floating roof. The common sealing forms include mechanical seal, elastic filling seal, lip seal and secondary seal. No matter what kind of seal, the seal must be combined with the floating roof effectively to reduce the evaporation loss of the liquid in the floating roof.The company strengthens process management and pays attention to assessment. One of the key points of good service is to strengthen the process management and improve the evaluation mechanism. Make the after-sales service system more perfect and provide better service for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!