The service life of API standard 650 aboveground petroleum storage tanks

API standard 650 aboveground petroleum storage tanks weld tightness test: remove dirt from the API standard 650 aboveground petroleum storage tanks weld, apply white powder emulsion, spray kerosene on the other side of the weld after drying. Because of the strong penetration of kerosene, if kerosene is sprayed after 12 hours (under low temperature conditions, the time can be extended), if the surface of the welded seam coated with white emulsion has no spots, the welded seam meets the requirements.

Heat-affected zone impact specimens shall be taken across the weld and as near the surface of the material as is practicable. The API standard 650 aboveground petroleum storage tanks material specimens shall be of sufficient length to locate the notch in the heat-affected zone after etching. The notch shall be cut approximately normal to the material surface to include as much heat-affected zone material as possible in the resulting fracture. Impact test specimens shall be cooled to the temperature stated in Q.22.

Upon completion of construction, provide Purchaser with copies of Field Erected API standard 650 aboveground petroleum storage tanks Storage Tank Datasheets in accordance with Appendix L of API 650, which reflects the as-built conditions, certifying that the tank conforms with the requirements of this specification.

Team concept: respect, communication, coordination and symbiosisBusiness philosophy: leading by strategy, driving by innovation, creating valueManagement concept: goal oriented, efficient operation, stimulation of vitality and continuous improvementQuality concept: standard guidance, control process, craftsman spirit, leading serviceTalent concept: lifelong learning, give full scope to the talents, the sea refuses no riverInnovation concept: innovation is the first driving force for the company's high-quality developmentCustomer concept: taking customers as the center is the foundation of the company's survival and development

If you want to get the ASTM A573 Grade 70/A573 Gr.70 carbon manganese silicon steel plates steel price, please do not hesitate to contact us. Any need in API standard 650 aboveground petroleum storage tanks ASTM A573 Grade 70/A573 Gr.70 carbon manganese silicon steel plates Chemical Composition and Mechanical Properties, please feel free to contact us by email or calling to us

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!