ASTM A420 pipe API Std 650 welded tanks for oil storage

Design of a Double-wall Tank
The outer bottom, shell, and roof of a double-wall tank shall enclose an insulating space around the bottom, shell, and roof or insulation deck of the inner tank that contains the stored liquid. The annular space shall be maintained at a low positive pressure, which necessitates that the enclosure be vapor-tight. The Purchaser shall specify the design metal temperature and pressure of the inner tank and may specify the design temperature and pressure of the outer tank API Std 650 welded tanks for oil storage. The Purchaser shall state the specific gravity of the content to be stored, roof live loads, wind load, earthquake load where applicable, and corrosion allowance, if any.

The working pressure of the low-pressure storage tank is greater than that of the atmospheric storage tank, but its pressure is less than 0.1MPa. API 650 petroleum storage tanks are classified according to their environment: Above-ground storage tank: refers to the bottom of the storage tank at the design elevation of API Std 650 welded tanks for oil storage and above; the bottom of the tank is below the design elevation of +0.00 but not exceeding.

LSAW Pipe to Peru. In the beginning of 2014, Peru government released an international tender for one of the hydroelectric power plant. Finally they chose us as the contractor, we purchased the steel plate and then fabricate the API Std 650 welded tanks for oil storage steel plate into steel pipe, and then make the corrosion protect on the surface, we also supply the fitting with our steel plate, the total value of this order is about 2 million USD.

}

The most popular standards for API Std 650 welded tanks for oil storage are API Std 650, JIS B8501, BS2654, GB50341, etc. The formulas used in each standard are derived from the hoop stress calculation formula of membrane theory. Combined with the stress characteristics of API Std 650 welded tanks for oil storage, plus the allowable stress, weld coefficient and additional wall thickness, the wall thickness calculation formula is complete. The allowable stress and weld coefficient are determined according to the material performance characteristics and construction technology level of each country. According to different API Std 650 welded tanks for oil storage standards, the calculation results of tank wall thickness are sometimes quite different.

First of all, we should establish a correct concept of after-sales service. Service concept is an important part of corporate culture and a long-term enterprise value concept. Our company's after-sales service embodies the concept of "customer first, sincere service for customers". As long as we are in the "sincere service for users" under the guidance of the idea, I believe we will get rich returns.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!