Design temperature of API Std 650 flat-bottom steel tanks

Treatment of API Std 650 flat-bottom steel tanks welding defects:
1. Lack of fusion: once found, it should be shoveled and grinded off before re welding.
2. Incomplete penetration: over standard defects shall be removed and re welded. When welding on both sides, the shallow side of the groove can be grinded and shoveled to expose the welding root on one side, and then the welding is repaired.
3. Slag inclusion: over standard defects shall be removed and re welded.
4. Crater: weld to full after grinding.
5. Air hole: if the internal air hole exceeds the standard, it shall be welded again after being removed by grinding shovel, and the surface air hole shall be removed by grinding wheel and then repaired.

API 620 storage tanks relative standard for referenceASTM A106 Seamless Carbon Steel Pipe for High-Temperature ServiceASTM A131 Shipbuilding Structural Steel for API Std 650 flat-bottom steel tanksASTM A134 Welded Steel PipeASTM A182 Forged or Rolled Alloy-Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-Temperature ServiceASTM A193 Alloy-Steel and Stainless Bolting MaterialsASTM A194 Carbon and Alloy Steel Nuts for Bolts for High-Pressure and High-Temperature ServiceASTM A213 Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat Exchanger TubesASTM A240 Stainless Steel Plate, Sheet, and Strip for Pressure VesselsASTM A283 Low and Intermediate Tensile Strength Carbon Steel Plates

The outer layer of API 650 tank is glass fiber reinforced plastic layer with a thickness of more than 2.5mm, which API Std 650 flat-bottom steel tanks has strong corrosion resistance and electric corrosion resistance. Special process technology is used between the two layers to make the gap reach 0.1 mm, so as to eliminate the existence of potential safety hazard from the root.

Booking space and making power of attorney (ten copies of order); the data of the original order shall be correct and consistent to the greatest extent when making the order, so as to reduce the frequent changes in the subsequent process. For booking with the company's seal for booking space, if the accessories for booking space (such as the price confirmation document of the shipping company) need to be provided, they can only be booked with all of them. Obtain the shipping space allocation receipt and extract the ship name, voyage number and B / L number information.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!