API Std 650 carbon steel tank roof load

The outer FRP of API 650 oil tank will not produce electrolytic corrosion with groundwater and brine. The outer FRP will not corrode with gasoline, diesel oil and leaded gasoline API Std 650 carbon steel tank. The leakage detector can monitor the whole process 24 hours to eliminate the potential pollution. The leakage detection system is convenient for the inspection and maintenance of API 650 oil tank, and protects the original ecological environment of soil and groundwater.

Weld inspection of API Std 650 carbon steel tank, vertical oil tank wall plate: In the welding inspection process of oil tank wall plate, attention should be paid to the defects of thick wall plate, such as incomplete penetration, incomplete root fusion and cracks. If there is a root incomplete penetration defect, it is necessary to open the weld joint with carbon arc air gouging and grinding machine grinding, or even weld through, and then weld again after the defect is removed.

The company uses online training system to let all employees use fragmented time to carry out targeted training anytime, anywhere, regardless of time and geographical restrictions. Through training to improve API Std 650 carbon steel tank work skills, at the same time, through training, let all improve their own quality education level, let employees work around a goal, create a career and achieve results.

API 620 Crude Oil Tank Non-pressure Parts
Welds for pads, lifting lugs, and other nonpressure parts, as well as temporary lugs for alignment and scaffolding attached to primary components, shall be made in full compliance with a welding procedure qualified in accordance with Q.6.1. Lugs attached for erection purposes shall be removed, and any significant projections of API Std 650 carbon steel tank weld metal shall be ground to a smooth contour. Plate that is gouged or torn in removing the lugs shall be repaired using a qualified procedure and then ground to a smooth contour. Where such repairs are made in primary components, the area shall be inspected by the liquid-penetrant method. A visual inspection is adequate for repairs in secondary components.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!