API standard 650 open top welded storage tanks ultrasonic examination
According to API 650 tanks, anchoring devices should be designed to transfer overturning moments to the API standard 650 open top welded storage tanks tank foundation. At the same time, according to API 650 tank Appendix F, when the tank is to be anchored, the size of the anchoring parts is determined by the maximum lifting force caused by the internal pressure and wind load or the combination of internal pressure and seismic load.
The after-sales service department will pay return visit to each customer by call or email, report problems found during the return visit in time, and discuss with the production and quality inspection center to propose effective solutions and follow up in a timely manner, so as to ensure the benefits each customer are fully guaranteed, and to provide customers with more value-added services.
Service Conditions and Hydrogen-induced CrackingWhen the service conditions might include the presence of hydrogen sulfide or other conditions that may promote hydrogen-induced cracking effects, particularly near the bottom of the API standard 650 open top welded storage tanks shell at the shell-to-bottom connections, care shall be taken to ensure that the materials and details of construction of the tank are adequate to resist hydrogen- induced cracking. The Purchaser shall consider restricting the sulphur content of the material to be stored through thickness testing of the steel, laboratory surveillance tests, and the use of internal tank coatings to reduce the possibility of hydrogen-induced cracking.
The engineering quality of API standard 650 open top welded storage tanks not only affects production and operation, but also affects the life safety of the staff. The factors affecting the API standard 650 open top welded storage tanks construction quality are all aspects, any link, any part of the problem will affect the whole project, so the quality management is paid more and more attention. How to ensure the engineering construction quality of oil tank? First, make API standard 650 open top welded storage tanks construction technical preparation carefully, understand the design intent, master the construction acceptance specification, and make detailed construction technical disclosure to the construction team.