API Std 650 open-top tanks manufacturer's standard drain
According to the standard of head of API Std 650 open-top tanks, there should be no crack, delamination, inclusion and other defects on the groove surface, which is consistent with the steel plate standard. The API Std 650 open-top tanks head polishing can adopt different technology according to different requirements, including rough polishing, medium polishing and fine polishing. Only the materials used for the third type of pressure vessels must be retested, and the materials used for the first and second class pressure vessels are not generally re inspected.
The insert plate weld shall not cross any shell seams and shall be at least the greater of 10 times the shell thickness or 12 in. from any other weld in the API Std 650 open-top tanks shell including shell seams, shell-to-bottom weld or attachment welds. The butt weld around the periphery of the plate shall be examined over 100% of its length by both liquid penetrant method and radiographic method. The liquid penetrant examination is required on the root pass, on the back-gouged surface, and on the inside and outside finished weld surfaces. Additionally, the weld shall be vacuum box leak tested.
Test welds of each API 650 tank nozzle and manway reinforcing pad (or each section of multiple piece pad) using dry air and apply a soap solution test in the presence of Purchaser's Inspector before hydro testing the API Std 650 open-top tanks tank. Tap one inch NPT test hole in each pad or section.
The company's business philosophy: customer satisfaction is the most important measure of our work performance; employees are the company's most important wealth; the improvement of employees' quality and professional knowledge is the growth of the company's wealth; employees' welfare and living standards are the concrete embodiment of the company's business performance; product and service quality are the lifeblood of the company's development; brand is the company's products and A mirror of service; recognition of the market is the foundation of the company's survival.
We have a good inventory system because of which the alloy steel plates and structural steel sheets are supplied and delivered to our customers on time. Our alloy steel plate is significantly affordable than austenitic API Std 650 open-top tanks stainless steel which helps to reduce maintenance and full life costs – as well as improved safety over standard boilerplate. Contact us today to request a quotation or email us with your complete specification, we are happy to help you!