API 650 fixed roof tanks tank anchorage
Cylindrical Oil storage tanks Discharge PipesWhen a discharge pipe is used on the outlet side of such relieving devices, its area shall be not less than the area of the valve outlet, or if a single pipe provides for discharge from several relief devices, its area shall be not less than the aggregate area of the valve outlets. The API 650 Fixed roof tanks discharge pipe shall be fitted with an open drain to prevent water or other liquids from lodging in the discharge side of the valves.Discharge pipes shall be supported so that no undue stress is placed on the valve body. Open discharges shall be placed and oriented so that the outflow is directed away from the tank and will not create a hazard over walkways, stairways, or operating platforms.
API 650 petroleum storage tank specifications and standards are documents verified by the customer (owner) under different operating conditions; however, API 650 fixed roof tanks it must be verified whether these API 650 petroleum storage tank documents are suitable for use and whether they comply with applicable design specifications and/or specifications.
The elastic filling and sealing of floating roof API 650 fixed roof tanks is to fill the elastic and changeable objects in the sealed envelope, and the sealing purpose depends on the compression deformation of the filler. This kind of sealing effect is good, the requirement of the geometry of tank wall is not too high, and the adaptability is strong. However, the elastic filling and sealing has poor wear resistance and is easy to deform and damage in long-term use.