API 650 aluminum tanks with a berm foundation

After more than 20 years of ups and downs in the steel industry, BBN company's customers have covered South America, North America, Europe, Africa, Southeast Asia and the Middle East and other countries and regions. We treat every customer who inquires with us sincerely, whether you cooperate with us or not, we will provide you with the best quality steel solutions. Our company team also support the online customer service.

Large-scale vertical API 650 aluminum tanks mostly use internal tank bottom heating coils to heat the medium stored in the storage tanks. The heating coils are mostly smooth tube structures arranged in an annular circle along the bottom of the API 650 aluminum tanks. Commonly used heating methods include hot oil circulation heating method and hot water steam circulation heating method. The hot oil circulation heating method is to continuously extract part of the liquid medium from the storage tank, and then return it to the container to mix with the medium in the tank after heating, and the heat is quickly transferred through mechanical stirring.

The materials used in the construction of Appendix Q oil tanks may be subject to severe pitting, cracking, or rusting if they are exposed to contaminated test water for extended periods of time. The Purchaser shall specify a minimum quality of test water that conforms to Q.8.3.2 through Q.8.3.8. After the water test is completed, the tank API 650 aluminum tanks shall be promptly drained, cleaned, and dried.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!