API Std 650 ground supported tanks top attachment
Preheating should be performed by heating and maintaining this heat in appreciable lengths of the joint to be welded, preferably using a strip burner with a mild flame rather than a harsh flame such as that from a cutting torch. Electrical strip heaters are available and have been found to be satisfactory. The preheat of 300°F should be checked with a temperature-sensitive crayon, or similarly accurate means, so that the steel 4 in. (or four times the API Std 650 ground supported tanks plate thickness, whichever is greater) on each side of the joint will be maintained at the minimum preheat temperature. Ring burners or heaters are recommended for nozzle and manway welds. At no time during the welding should the base metal fall below a temperature of 300°F.
The API 650 specification provides guidelines for the API Std 650 ground supported tanks design, manufacturing, materials, installation and inspection of welded vertical and cylindrical tanks. Such containers must be on the ground and have a closed or open top.
In 2016. Our company offer 1200 tons API 5L GR.B hot rolled coil to Bangladesh——100 tons for 3.9*625mm, and 1100 tons for 7*683mm. It is one tender project, we get the tender at the end of 2015, and arrange the production in 2016. They required the tolerance of thickness is +0.1/-0.2mm, and width tolerance is +/-0.5mm, which is a very high requirement for coil tolerance, but our mill handling this very well. and our Q/C department witness all of the process.
}Static storage loss is also known as "small breathing" consumption. The rise and fall of the temperature in the API Std 650 ground supported tanks leads to the increase and decrease of the pressure in the tank, which makes the mixed oil gas discharged from the tank, and the external air is sucked into the tank, resulting in the oil consumption. Fluid level loss is also called "big breathing" loss. It is the oil consumption caused by the change of gas space volume in the API Std 650 ground supported tanks during the oil receiving and sending operation, which causes the mixed oil gas to be discharged out of the tank, and the external air is sucked into the tank, resulting in the oil consumption due to the change of liquid level height.
To provide customers with the most satisfactory service and realize the win-win of economic and social benefits, our company promises to provide excellent API Std 650 ground supported tanks products in this bidding, and in line with the attitude of being serious and responsible to customers, before sending goods to users, the API Std 650 ground supported tanks technical personnel shall confirm that there is no fault in the equipment before sending goods to users, and then send goods and products to users, and formulate the following service terms.