API Std 650 closed top welded storage tanks NPS 8 sample hatch

API Std 650 closed top welded storage tanks Oil measuring hole: The oil measuring hole is used to measure the height, temperature and sampling of the oil stored in the tank, and is installed near the tank top platform. API Std 650 closed top welded storage tanks Fire extinguisher: The fire extinguisher (also known as the flame arrestor) of the oil tank is composed of a fire box, a copper wire mesh and an aluminum partition. It is installed under the breathing valve or safety valve to prevent sparks and air from entering the inside of the tank through the breathing valve or safety valve and causing accidents.

Investigation of Subgrade
On actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.
In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.

We have Business Department, Transportation Department, Document Department, Shipping Department, E-C department, Procurement Department, Finance Department, Human Resources Department, Administration Department, Logistics Department, After-sales so on Departments. Each department performs its own duties, unites and cooperates, and contributes its greatest strength to the overall operation of the company. So as to ensure the stable and sustainable development of the company.

This standard only applies to API 650 storage tanks API Std 650 closed top welded storage tanks with uniform bottom support and non-refrigerated service storage tanks with a maximum design temperature of not more than 93 degrees Celsius (200 degrees Fahrenheit).

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!