API standard 650 welded storage tanks division of responsibility
Large Steel storage tank AnchorageIn addition to the loads in API 620 oil storage tank Q.4, Q.5.1, and Q.5.2, the anchorage for the tank that contains liquid, whether it be a single-wall tank or the inner tank of a double-wall tank, shall be designed to meet the requirements of Q.3.6.2 through Q.3.6.5. The anchorage shall accommodate movement of the tank wall and bottom caused by thermal changes. For anchored flat-bottom tanks, the anchorage shall be designed as described in Q.3.6.4.1 through Q.3.6.4.3.
When API 650 storage tank is designed, when the design pressure is small F2 kPa, the impact of air pressure on the API standard 650 welded storage tanks tank wall thickness is not considered in the tank wall design.
Strictly control the welding groove forming of API standard 650 welded storage tanks: in order to ensure the geometric dimension of assembly and good welding of welding seam, before hoisting and laying, the edge of all metal vertical storage tank plate shall be polished by grinder, and the flatness of plate shall be ensured according to the design requirements. Strictly control the size of API standard 650 welded storage tanks weld assembly: measures must be taken to strictly control the assembly size of metal vertical tank bottom plate during assembly.