A516 Gr 380 plates API 650 self anchored flatbottom tanks
For employees' development, the company's transformation and development provides employees with a broad career development platform. The company needs "lion-type" entrepreneurial leaders who are full of entrepreneurial enthusiasm and dare to self-renovate. They also need a large number of professional and professional high-quality talents, and employees can get full capacity to display opportunities.
Inspection of weld and micro crack of API 650 self anchored flatbottom tanks: the inner and outer surface of API 650 self anchored flatbottom tanks, weld and heat affected zone shall be observed by naked eyes first. 100% ultrasonic testing or 100% penetrant testing are carried out for butt welds of API 650 self anchored flatbottom tanks. For the defects found by 100% magnetic particle inspection, dye detection, 100% ultrasonic inspection or 100% penetrant inspection, the radiographic inspection shall be used again to ensure the accuracy of the test results.
Soil Structure Interaction: Soil structure interaction per API 650, Section E.6.1.6 may be used for OLE design providing the damping ratio does not exceed 10 %.Allowable StressesDesign allowable stresses shall be per API 620 large welded steel storage tank, Section Q.3.3, including the 33 % increase permitted for earthquake loads.Self-anchored Inner TankThe anchorage ratio for a self-anchored inner tank, J, shall not exceed 1.0 for the OLE design combination to limit uplift and stresses in the annular plate and corner weld.Foundation StabilityThe overturning ratio defined in API 650, Section E.6.2.3, Equation (E.6.2.3-1) shall be equal to or greater than 3.0 for the defined OLE event.