API standard 650 self-anchored tanks greater than 60 m in diameter
API standard 650 self-anchored tanks Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.
API 650 storage tank stipulates that if the thickness of the lower wall panel obtained by calculating the anti-overturning moment is greater than the thickness of the API standard 650 self-anchored tanks hydrostatic pressure test (both do not include the corrosion allowance).
BBN steel had provided Grind plates for more than 15 years for widely applied in equipment, Engineer machinery etc. In 2018, one of our India customer visit our API standard 650 self-anchored tanks office and work shop to discuss Q235B Grind plate technical request, they have strict surface and thickness tolerance, and they also request UT and MT for testing. As a result, they purchase API standard 650 self-anchored tanks 179 tons as trial order for first cooperation. And have good comment on our quality. Till now, we keep exporting around 100 tons per month as regularly.
}The safety inspection of atmospheric storage tank, API standard 650 self-anchored tanks is divided into external inspection, internal and external inspection and comprehensive inspection. External inspection shall be conducted at least once a year, internal and external inspection shall be conducted at least once every three years, and comprehensive inspection shall be conducted at least once every six years. The safety inspection of large atmospheric storage tanks, API standard 650 self-anchored tanks requires special attention: the parts where the liquid level often fluctuates, the parts that are susceptible to corrosion, and the parts that are deformed and worn during use should be checked.
Our company has established and constantly improved the customer service system and emergency response system. Through the customer service management system, we track the service of the after-sales service team and provide efficient and standard services in time. At the same time, the company formulates a regular return visit system, compares the historical cases of customer problems, proposes a pre solution, and ensures that the service is in place in a short time.