API 650 welded steel oil storage tanks adjustable legs
The refrigerated tank primary components shall include, but will not be limited to, the following parts of a single-wall tank or of the inner tank API 650 welded steel oil storage tanks in a double-wall tank: shell plates; bottom plates; knuckle plates; compression rings; and shell manways and nozzles including reinforcement, shell anchors, piping, tubing, forgings, and bolting. Roof nozzles in contact with the refrigerated liquid shall be considered primary components.
Under the same sealing effect, the internal floating roof tank of API 650 oil storage tank can further reduce the evaporation loss compared with the API 650 welded steel oil storage tanks External floating roof tank. This is due to the shielding of the fixed roof and the gas layer between the fixed roof and the internal floating plate, which has more significant heat insulation effect than the double disc floating roof of the API 650 welded steel oil storage tanks external floating roof tank.
The cone slope of the completed API 650 welded steel oil storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API 650 welded steel oil storage tanks should have at least 4 detection tubes.