A737 grade B plates API 650 insulated tanks
The manufacturing requirements of bottom plate of vertical metal tank, API 650 insulated tanks are as follows: 1. In order to compensate welding shrinkage, the layout diameter of tank bottom is 5-2mm than the design diameter; 2. The butt joint of edge plate of tank bottom shall be machined automatically or semi-automatically; 3. The distance between any two adjacent welding joints on the tank bottom plate and the distance between the butt joint of edge plate and the longitudinal weld of bottom ring wall plate shall not be greater than 200 mm.
API 620 storage tanks relative standard for referenceAPI Spec 5L, Specification for Line PipeAPI RP 520, Sizing, Selection, and Installation of Pressure-relieving Devices in Refineries, Part II—InstallationASME B31.3, Chemical Plant and Petroleum Refinery Piping (ANSI/ASME B31.3) ASME B36.10M, Welded and Seamless Wrought Steel Pipe (ANSI/ASME B36.10) ASME B96.1, Welded Aluminum-Alloy Storage Tanks (ANSI/ASME B96.1)ASTM A36 Structural Steel for API 650 insulated tanksASTM A53 Zinc-Coated Welded and Seamless Pipe
Under the same sealing effect, the internal floating roof tank of API 650 oil storage tank can further reduce the evaporation loss compared with the API 650 insulated tanks External floating roof tank. This is due to the shielding of the fixed roof and the gas layer between the fixed roof and the internal floating plate, which has more significant heat insulation effect than the double disc floating roof of the API 650 insulated tanks external floating roof tank.