EN 10025 S355JK plates API 650 self-anchored tanks

Customer service center has provided after-sales service for many large-scale information systems, and has accumulated rich working experience in the process of API 650 self-anchored tanks service for many years. It can provide accurate, timely and high-quality support and service for users, which is well received by users.

The main reason of "small breathing" loss of API 650 self-anchored tanks is the change of atmospheric temperature. When the temperature rises with the increase of solar radiation from dawn, the temperature of oil in the API 650 self-anchored tanks also changes, resulting in the acceleration of evaporation speed and the increase of evaporation pressure. When the pressure exceeds the positive pressure rating of the breathing valve, the oil-gas mixture in the API 650 self-anchored tanks is discharged into the atmosphere through the breathing valve, which is the "exhalation" process of the oil tank.

Data Required from Manufacturer on Completed TanksIf specified in the purchase order, the Manufacturer shall supply marked copies of plans (or a separate sketch) showing the location of all plates, with a means of identifying each plate with the heat numbers. These markings shall be checked by the inspector. A copy shall be attached to the Manufacturer’s report.Check of Stress-relieving OperationThe API 650 self-anchored tanks inspector shall check any thermal stress-relieving operation and shall be satisfied that the temperature readings are accurate and that the procedure conforms to the applicable requirements of these rules.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!