Closed- and open top API standard 650 welded steel oil storage tanks

The company has a group of mature steel plate production and processing line construction and production management experience. In addition, the company has professional and technical personnel. BBN steel is a modern enterprise integrating scientific research and development, production processing, sales and service. The company now has finance department, production department, sales team, technical department, quality control department, logistics department and after-sales service team. At the same time, it also adheres to international standards and adheres to the international line.API 620 Steel Oil Tank Bottom and Shell Support
The tank API standard 650 welded steel oil storage tanks under-bottom insulation shall be designed to resist the combined pressures from the product load, the overturning seismic load and the vertical seismic load. These seismic pressures may be combined by SRSS.
The bearing ring under the shell shall be designed to resist the calculated OLE peak compressive force in the tank shell due to overturning (see API 650 oil tank, Section E.6.2.2), including dead and live loads. A 33 % increase in allowable bearing stress is permitted.Lateral braces between outer bay rafters must be provided if asymmetrical structural shapes are used for rafters and if the API standard 650 welded steel oil storage tanks API 650 tanks are located in areas subject to earthquakes. The bracing must be adequately sized for the seismic zone specified.We have a stable system and professional human resource management work as the support, from the six aspects of guidance, cohesion, incentive, constraint, radiation and stability, we continue to introduce, modify and train employees from concept to action, and shape employees through constant guidance of common values.Volatilization is the characteristic of oil. Under normal temperature and pressure, as long as the oil is in contact with air, the surface will volatilize. Through scientific analysis and summary, the causes of oil volatilization loss in API standard 650 welded steel oil storage tanks are: natural ventilation loss, static storage loss, dynamic liquid level loss. In the use of API standard 650 welded steel oil storage tanks, static storage loss and dynamic liquid level loss are common losses.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!