ASTM A27 grade 65-35 floating roofs API 650 flat-bottom tanks
The interior of API 650 storage tanks to be internally lined or coated must have all edges rounded to a minimum of 3 mm radius. Internal welds must be completely seal welded, ground smooth, and free from API 650 flat-bottom tanks surface porosity, pockets, and high spots. Remove weld spatter. Vendor as specified on API 650 storage tanks drawing must perform additional surface preparation.
The finned tube heating device for high temperature heat transfer oil for large API 650 flat-bottom tanks has the advantages of convenient inspection and maintenance. The high-efficiency fin heating coil assembly is composed of spirally arranged finned coils. The fins are mainly arranged in the straight pipe section, and the whole assembly is supported by several angle steel supports. The high-efficiency fin heating coil component can enter and exit from the manhole of the API 650 flat-bottom tanks, which is convenient for maintenance and repair.
Investigation of SubgradeOn actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.
When talking about our team, it is hard not to mention our QC department (Quality Control). We have built strict qualitycontrol system to guarantee the steel quality. During the steel materials production, we have strict monitoring measures and indicators, and ensure no chemical composition, mechnical properties and so on technical problems for the steel materials API 650 flat-bottom tanks. After production, our QC department will conduct another inspection regarding to the steel quantity, dimension, mark and so on points before delivery.
In the process of API 650 flat-bottom tanks steel transportation, enterprises often use railway transportation, highway transportation, water transportation and other ways to transport. According to the cargo owner's requirements on the timeliness of the goods and the different transportation routes, our company will choose API 650 flat-bottom tanks different modes of transportation. According to the specific needs of customers, or specify the mode of transportation.