How to effectively increase the service life of API 650 open top welded storage tanks oil tanks? It is necessary to check and inspect the oil tank regularly in the process of use, and do a good job in the maintenance and cleaning of the oil tank. The oil tank should be inspected every 6 years. With the increase of service life, the inspection interval should be shortened. Daily maintenance and cleaning of the API 650 open top welded storage tanks can prolong the service life of the oil tank. The maintenance of the API 650 open top welded storage tanks mainly includes the anti-corrosion inspection of the oil tank, the maintenance of the accessories, and the cleaning of the sediment in the tank.

Customer first, reputation first, high-quality and perfect after-sales service is the extension of our product value and an important guarantee for the interests of customers. The purpose of our API 650 open top welded storage tanks service quality management system is to establish and constantly improve a scientific, reasonable and efficient service quality management system, and complete the after-sales service quality guarantee work of customers fairly, accurately and timely, For our company's API 650 open top welded storage tanks customer service to establish a good, comprehensive, full service system.

Determination of Required Capacity
The aggregate capacities required for any vent valves, pressure-relieving valves, and/or vacuum-relieving valves to be provided should be determined as follows:
a)For thermal breathing and product movement, the rules given in API 2000 shall be followed. The required capacity as the result of the product movement into the tank API 650 open top welded storage tanks given in API 2000, shall be multiplied by the ratio of the absolute tank pressure to atmospheric pressure (14.7 lbf/in.2 absolute).
b)For supplemental safety pressure-relieving devices to take care of extra venting capacity required in case of external fire exposure, the rules in API 2000 shall be followed.

This specification, in conjunction with API 650 Standard, prescribes minimum standards for the API 650 open top welded storage tanks design, supply, fabrication, erection, and testing of field erected welded steel storage tanks complete with accessories as specified herein and as shown on attached Datasheets and/or Drawings.