API Std 650 ground supported flat-bottom tanks threaded connections

The thickness of the API Std 650 ground supported flat-bottom tanks annular bottom plates shall be in accordance with Table Q-4 (for steel or aluminum, as applicable). The thicknesses shown are minimums. The ring of annual plates shall have a circular outside circumference, but it may have a regular polygonal shape inside the tank shell with the number of sides equal to the number of annular plates. These pieces shall be butt-welded in accordance with Q.7.1.1, Item b. The plates of the first shell course shall be attached to the annular bottom plates by a weld as required by API 620 oil tank 5.9.5 except when a full-penetration weld is used or required (see Q.7.1.1). Butt-welds in annular plates shall be not closer than 12 in. from any vertical weld.

API 650 storage tank, double-layer oil tank environmental protection advantages: ordinary single-layer steel API Std 650 ground supported flat-bottom tanks oil tank is corroded by underground water and gas and electrolytic corrosion because it is buried underground all year round. The API 650 tank has a double-layer structure with a gap of 0.1 mm. The API Std 650 ground supported flat-bottom tanks outer layer of FRP ensures that the leakage will not directly leak into the soil and water source.

In October 19th 2018, our Malaysia customer purchased 600 Tons CCS Grade AH36 mairne steel API Std 650 ground supported flat-bottom tanks plates to use in their shipbuilding project .This customer is a famous shipyard company in Malaysia. Their company has the business scope of tourism, shipbuilding, transportation and so on. As a terminal manufacturer, they have strict requirements on quality for CCS Grade AH36 mairne steel plates. After visiting our steel milll, the customer is very satisfied with the quality of this batch of CCS Grade AH36 steel plates.

}

Strictly control the welding groove forming of API Std 650 ground supported flat-bottom tanks: in order to ensure the geometric dimension of assembly and good welding of welding seam, before hoisting and laying, the edge of all metal vertical storage tank plate shall be polished by grinder, and the flatness of plate shall be ensured according to the design requirements. Strictly control the size of API Std 650 ground supported flat-bottom tanks weld assembly: measures must be taken to strictly control the assembly size of metal vertical tank bottom plate during assembly.

Due to other non-steel quality reasons caused by the customer dissatisfaction, to timely explain to the customer, and help them solve the problem, for the customer really because of their own reasons, to give patient reply.The process of objection handling is the process of our technical service.