API standard 650 self-anchored tank gauging device
In cylindrical tank walls, the longitudinal weld joints in adjacent shell courses, including compression ring welds, shall be offset from each other a minimum distance of 12 in. The butt-weld around the periphery of a thickened insert plate, or the fillet weld around the periphery of a reinforcing plate, shall be at least the greater of 10 times the shell thickness or 12 in. from any butt-welded seam or the bottom-to-shell or roof-to-shell joint. As an alternative, the insert plate (or the API standard 650 self-anchored tank reinforcing plate in an assembly that does not require stress relief) may extend to and intersect a flat-bottom-to-shell corner joint at approximately 90 degrees.
API 650 Application As described by the American Petroleum Institute, the fabrication and installation of our surface welded API standard 650 self-anchored tank steel storage tanks is normally used in industrial applications. In general, our standards for industrial on-site installation of storage tanks are established according to API 650, API 620 and API 12D.
In January, 2019, our South Africa customer purchased 669 tons S235J2+N carbon steel plates to use in their tank fabrication project . S235J2 steel, as a non-alloy structural steel grade, is mainly used in structural projects and tanks. J2 symbol -20 temperature impact test. The client required CEV 0.38%, S≤0.01%, 100% UT, Charpy V-notch impact test at-20℃, Z25 for S235J2+N plates. After they receiving the S235J2+N steel plates, the customer are very satisfied with the quality of this batch of API standard 650 self-anchored tank products.
}The structure of the API standard 650 self-anchored tank foundation mainly includes the insulating anticorrosion layer on the top surface of the foundation, the tank wall support, the edge retaining structure, the sand cushion, the oil and water barrier, the detection signal tube and other structures. The construction materials and requirements of each basic structure of the storage tank are different. After the structure of the API standard 650 self-anchored tank foundation is built in accordance with the construction requirements, the settlement of the storage tank foundation needs to be observed, and the uneven settlement value of the storage tank foundation should be within the allowable safety range.
After the order is finished, our after-sales service center will send an email to make a feedback about our steel products' quality. We have phone service every three months to remind our customers of the possible problems and collect advices or suggestions in quality and service. Upon the collection of advices or suggestions, our after-sales service will quickly make technical solutions to wipe out the customer problem.