API standard 650 anchored tanks design spectral response accelerations
The main types of metal storage tanks are vertical dome roof tank, vertical external floating roof tank, vertical inner floating roof tank, spherical oil tank and horizontal oil storage tank. API standard 650 anchored tanks is vertical tank. The capacity of vertical dome roof oil storage tank is generally less than 10000 cubic meters. The wall plate adopts sleeve type fillet weld, and it is usually installed by inverted or forward installation method during construction.
Shell Stiffening Rings for Tanks That Contain Liquid: Internal or external shell stiffening rings may be required to maintain roundness when the API standard 650 anchored tanks is subjected to wind, vacuum, or other specified loads. When stiffening rings are required, the stiffener-to-shell weld details shall be in accordance with Figure R-1 and R.3.5.2 through API Standard 620 R.3.5.5. Three-plate laps or butt-weld junctions in the tank bottom shall be not closer than 12 in. from each other and/or the butt-welds of the annular plate.
API 650 petroleum storage tanks use lightning protection, anti-static, and fire protection measures. The internal corrosion protection should be determined according to the API standard 650 anchored tanks storage medium, and the outer wall corrosion protection should be determined according to the soil quality of the buried tank.