API Spec 5L pipe API Std 650 fixed roof tanks

As a leading international steel supplier, we have two warehouses, close to Tianjin port and Shanghai port. This superior geographical location effectively saves the domestic transportation cost and greatly improves our service level. At the same time, it also shortens our delivery time and provides more convenience for customers.Inspection of Welded storage tanks Surfaces Exposed during FabricationThe edges of API Std 650 Fixed roof tanks plates, openings and fittings exposed during fabrication shall be inspected carefully to make sure that any defects have been uncovered, as well as to determine that the work has been performed properly.Minor defects found may be repaired only after the inspector approves the method and extent of repairs. Materials that have more than minor defects that cannot be satisfactorily repaired shall be rejected.Spot radiographic or ultrasonic examination shall be not less than 6 in. extending along the weld. Spot radiography shall comply with the standards given in 7.15.1.3. Where spot radiographic or ultrasonic examination is applied at joint intersections, the surface shall be prepared and examined for a distance of 3 in. on each side of the intersection, making the minimum length of examination 6 in. on the horizontal weld and 3 in. on the vertical weld.If you want to get the ASTM A573 Grade 70/A573 Gr.70 carbon manganese silicon steel plates steel price, please do not hesitate to contact us. Any need in API Std 650 fixed roof tanks ASTM A573 Grade 70/A573 Gr.70 carbon manganese silicon steel plates Chemical Composition and Mechanical Properties, please feel free to contact us by email or calling to usThe Standard has gained international recognition and is the standard of choice of most builders of large liquid above ground API Std 650 fixed roof tanks storage tanks. One reason for this is that the API 650 Standard was created and is revised by API committees comprised of the world s best tank structural engineers who also rely on the experience of tank owners and tank construction companies.Prefabrication requirements of large vertical API Std 650 fixed roof tanks accessories: the prefabrication shall be deepened as far as possible in strict accordance with the requirements of construction drawings and specifications, according to the principle of convenient installation and construction, as much as possible to reduce the installation workload, especially the workload of high-altitude operation. The prefabricated accessories shall be strictly inspected to ensure the quality and make marks. In addition, effective measures should be taken to prevent deformation, damage and corrosion during storage, transportation and stacking on site.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!