API 650 anchored tanks double-flanged nozzles
The API 650 anchored tanks most widely used and most commonly used standard for global storage tank construction and procurement is API 650. The Chinese translation name is "AP1650 Steel Welded Petroleum Storage Tank". API 650 storage tank is for commonly used oil, gasoline, diesel, chemical and production water storage, etc.
Compared with the external floating roof API 650 anchored tanks, the internal floating roof API 650 anchored tanks has the advantages of protecting the floating roof from wind and rain and ensuring the quality of liquid storage under the floating roof. At the same time, because the inner floating plate is in the tank, there is no rain and snow load, so the central drainage pipe and escalator and other accessories on the floating plate can be omitted. In addition, under the same sealing conditions, the internal floating roof tank can further reduce the evaporation loss compared with the External floating roof tank.
API Standard 620 tank Appendix C describes the factors involved in obtaining adequate foundations for tanks that operate at atmospheric temperature. The foundations for refrigerated tanks are complicated because of the thermal movement of the tank, the insulation required for the bottom, the effects of foundation freezing and possible frost heaving, and the anchorage required to resist uplift. The services of a qualified foundation engineer are essential. Experience with tanks in the area may provide sufficient data, but normally a thorough investigation, including soil tests, would be required for proper design of the foundation.
Every after-sales service shall have a detailed record of the customer's product problems and handling methods. The records shall be sorted into volumes and filed on a monthly basis, and submitted to the technical department for filing. The problems found in the after-sales service shall be summarized in a timely manner, discussed with the technical department, the quality inspection department and the production department, and a proper solution shall be proposed for the technical department to improve in a timely manner;
Booking space and making power of attorney (ten copies of order); the data of the original order shall be correct and consistent to the greatest extent when making the order, so as to reduce the frequent changes in the subsequent process. For booking with the company's seal for booking space, if the accessories for booking space (such as the price confirmation document of the shipping company) need to be provided, they can only be booked with all of them. Obtain the shipping space allocation receipt and extract the ship name, voyage number and B / L number information.