A662 Gr C plates API standard 650 floating-roof tanks

Investigation of Subgrade
On actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.
In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.

The internal floating plate of internal floating roof tank of API 650 tank is different from that of open floating plate of API standard 650 floating-roof tanks External floating roof tank of API 650 tank, so it is impossible to have rain and snow load.

BBN steel had provided Grind plates for more than 15 years for widely applied in equipment, Engineer machinery etc. In 2018, one of our India customer visit our API standard 650 floating-roof tanks office and work shop to discuss Q235B Grind plate technical request, they have strict surface and thickness tolerance, and they also request UT and MT for testing. As a result, they purchase API standard 650 floating-roof tanks 179 tons as trial order for first cooperation. And have good comment on our quality. Till now, we keep exporting around 100 tons per month as regularly.

}

The factors affecting the "small breathing" loss of API standard 650 floating-roof tanks are: 1. It is related to the change of temperature difference between day and night. The greater the change of temperature difference between day and night, the greater the loss of "small breathing"; on the contrary, the smaller the change of temperature difference between day and night, the smaller the loss. 2. It is related to the sunshine time of the oil storage tank. The longer the sunshine, the more the "small breathing" loss; otherwise, the less the loss.

Through the operation and management, brand advantage and improve pre-sales, sale of after-sales service, the efforts of the company into the industry leading enterprises.Relying on perfect quality management system, it has built up competition predominance and provided high quality, favorable price and perfect after service for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!