A537Cl1 plates API 650 fixed roof tanks
Investigation of SubgradeOn actual steel storage tank sites to be used, test borings or test pits, or both, may be made at the direction of a competent engineer who will specify the number and location. They need not be equally spaced but should be laid out to uncover possible weak spots.In general, test loadings of subgrade at the bottom of test pits need be resorted to only when such heavy loading as may be imposed by footings for major column supports for spheres or similarly elevated API 620 low-pressure tanks is specified. Results may be deceptive if average load-bearing capacity over a considerable area is wanted. All field data shall be recorded with maps, and copies shall be supplied to all engineers concerned with design, erection, and later operation.
The API 650 Fixed roof tanks external floating roof tank of API 650 tank has many advantages, and its application range is more and more wide. It is a kind of storage tank with a bright future. The well-designed internal floating roof tank of API 650 tank is the best and least investment method to control evaporation loss of API 650 fixed roof tanks fixed roof tank.
We have lots of successful cases, for example in July 2015, we exported 5714 tons ASTM A36 mild steel plate to Peru. After receiving the plates and putting then into use, our customer spoke highly of the ASTM A36 mild steel plate quality. In addition, the customer also introduced us an Venezuela customer, who bought 933 tons A36 steel API 650 fixed roof tanks plate from us. And then in Mar. 2016, due to the first cooperation in July 2015 is very successful. The customer is very satisfied with our product quality and comprehensive service. This time, the customer place an 3989 tons order directly.
}Welding inspection of bottom plate of API 650 fixed roof tanks, vertical oil tank: During the fabrication and installation of API 650 fixed roof tanks, the bottom edge plate is welded first. According to the requirements of the technical standard, penetrant inspection is required for the weld of edge plate at the bottom of API 650 fixed roof tanks, that is, penetrant testing is required for each weld bead priming, filling and capping. In the process of testing, if any defect is found, it shall be repaired immediately. After the repair, the surface coloring penetrant test shall be conducted again until the test result is qualified.
First of all, we should establish a correct concept of after-sales service. Service concept is an important part of corporate culture and a long-term enterprise value concept. Our company's after-sales service embodies the concept of "customer first, sincere service for customers". As long as we are in the "sincere service for users" under the guidance of the idea, I believe we will get rich returns.