30m diameter API Std 650 welded aluminum storage tanks
The cone slope of the completed API Std 650 welded aluminum storage tanks foundation is 15/1000 for the general foundation and less than 35/1000 for the soft foundation. After the foundation settlement of the storage tank is basically stable, the surface slope must be greater than eight thousandths. The edge of the tank bottom should be more than 0.3 meters higher than the surrounding ground. Above the ground, the tank bottom leakage detection tube should be drawn from the foundation sand cushion and cross the foundation ring wall or the slope protection surface. The circumferential distance should be less than 20 meters, and each API Std 650 welded aluminum storage tanks should have at least 4 detection tubes.
Inspection of Butt-welds in PipingButt-welds in piping and in API Std 650 welded aluminum storage tanks pipe fittings within the limitations of 1.3.2 (including the annular space of double- wall tanks) shall be inspected in conformance with API 620 oil tank standard Q.7.7.2 through Q.7.7.6. Longitudinal welded joints in piping that contains liquid shall be completely radiographed except for manufactured pipe welded without filler metal, 12 in. or less in diameter, which is tested hydrostatically or by eddy current to ASTM requirements.
BBN can provide design, manufacture and installation of API 650 large oil and crude oil storage tanks. We can build a API Std 650 welded aluminum storage tanks 7,000,000 gallon API 650 petroleum storage tank. In addition, BBN has the means to construct multiple storage tanks at the same time. We are very experienced in providing API 650 petroleum storage tanks.