3003 aluminum tube API 650 flat-bottom tanks
Requirements for prefabrication of bottom plate of large vertical API 650 flat-bottom tanks:1. The diameter of tank bottom should be enlarged by 0.1% ~ 0.15% according to the design diameter.2. The minimum dimension of edge plate along the radius direction of tank bottom shall not be less than 700mm.3. The distance between any adjacent welds of the base plate shall not be less than 300 mm.
Design of a Double-wall TankThe outer bottom, shell, and roof of a double-wall tank shall enclose an insulating space around the bottom, shell, and roof or insulation deck of the inner tank that contains the stored liquid. The annular space shall be maintained at a low positive pressure, which necessitates that the enclosure be vapor-tight. The Purchaser shall specify the design metal temperature and pressure of the inner tank and may specify the design temperature and pressure of the outer tank API 650 flat-bottom tanks. The Purchaser shall state the specific gravity of the content to be stored, roof live loads, wind load, earthquake load where applicable, and corrosion allowance, if any.
The API 650 is the American standard for welded flat-bottomed vertical API 650 flat-bottom tanks storage tanks. This standard dictates tank design, manufacture, welding, inspection and installation requirements.