The construction of foundations for API 650 flexible liquid storage tanks
The tank 20-in. inside-diameter nozzle shown in Figure F-6 is located in solid plate in the sidewall of a cylindrical storage tank 148 ft in diameter in an area where the thickness of the wall plate, tw, is 11/2 in. A corrosion allowance of 0.10 in. is required on all surfaces of the tank exposed to the stored liquid. The total internal pressure, Pl + Pg, at the center of the opening is 24.9 lbf/in.2 gauge. The thickness of the API 650 flexible liquid storage tanks wall plate, t, required by 5.10.3 for the latitudinal unit forces, T2, acting at this level is 1.44 in.
The working pressure of the low-pressure storage tank is greater than that of the atmospheric storage tank, but its pressure is less than 0.1MPa. API 650 petroleum storage tanks are classified according to their environment: Above-ground storage tank: refers to the bottom of the storage tank at the design elevation of API 650 flexible liquid storage tanks and above; the bottom of the tank is below the design elevation of +0.00 but not exceeding.
We have built solid cooperation with Myanmar Navy since 2015, starting from a try order about 412 tons LR AH36 shipbuilding steel plates. Myanmar navy builds frigate every year and book shipbuilding steel materials from us regularly. This time, the Myanmar navy’s local representative visit us and put another order about 2025 tons LR grade A steel plates. According to clients requirements, we arranged API 650 flexible liquid storage tanks SGS inspection for the LR grade A steel plates before shipping and send them inspection report.
}Prefabrication requirements of API 650 flexible liquid storage tanks, large vertical storage tank wall panels:1. The prefabrication of wall panel shall be processed in strict accordance with the requirements of the drawings, and inspection records shall be made.2. After the wall panel is rolled, it should be placed on the platform for inspection with a template. In the vertical direction, use a straight-line template to check, the gap should not be greater than 2 mm, and in the horizontal direction, use an arc-shaped template to check, and the interval should not be greater than 4 mm.3. When wall panels are rounded, attention should be paid to prevent irreversible plastic deformation caused by external forces. After rolling, it should be placed on the platform for inspection, and then placed on the prepared mold.
The after-sales service personnel understand the user's ideas and needs in detail, and stand on the other side's position and interests. Actively communicate with users and help them solve practical problems. This not only solves the service problem, but also improves the customer's trust in the company.