ISO 630 plates API Std 650 ground supported liquid storage tanks
In this project, a cylindrical tank 62 ft 6 in. in diameter is designed for an internal pressure of 4 lbf/in.2 gauge in the vapor space. The plate material is ASTM A131 steel with appropriate grades for different plate thicknesses in accordance with Table 4-1 for a design metal temperature less than 65°F but not less than 25°F. No corrosion allowance is required for any portion of the tank. The top course of the butt-welded cylindrical sidewall is 1/4 in. thick. The roof is a single lap-welded spherical dome with an internal radius of 50 ft and a thickness of 1/4 in. The maximum design liquid level is 6 in. below the plane of the juncture of the tank API Std 650 ground supported liquid storage tanks roof and sidewall.
Large net shell API 650 tanks or net shell of tank API Std 650 ground supported liquid storage tanks is a tank top for the surface grid structure and the physical structure form of truss structures, thin shell structure is reasonable, mainly for the top using triangle net shell, socket type net shell or meridian reticulated shell technology for the design of API Std 650 ground supported liquid storage tanks large-scale tank top, its great spanning capacity and uniform stress, good rigidity, less material, convenient assembly, safe and reliable.
Square hollow section S355J2H to Turkey. In January of 2015, our customer from Turkey chose us as their supplier of seamless RHS EN10219 S355J2H with a trail order of 120 tons. They required DNV test for the MTC and each tube. DNV inspector tested all the tubes and MTC. When our customer received the reports, they gave us a second order of 852.5 tons. Since then we maintain a long time cooperation relationship.
}No matter what type of storage tank needs to be built, the natural conditions of the geographical area where the tank is located should be fully considered in the design. Because natural conditions will affect the service life, storage safety and construction cost of storage tanks such as API Std 650 ground supported liquid storage tanks. Generally, the natural conditions that need to be considered before API Std 650 ground supported liquid storage tanks design and construction are: regional temperature, wind load, snow load, ground endurance, external environment corrosion, etc.
If customers have any difficult problems during use of the steel materials, they can contact the company's after-sales service department to feedback the existing problems. The after-sales department will reply as soon as possible to ensure that each customer has a good after-sales experience. Under special circumstances, the after-sales service department will start the problem-solving process, and the engineers in charge of the area will quickly follow up to solve the problem.