Fabrication of API standard 650 flexible liquid storage tanks
In this project, a cylindrical tank 62 ft 6 in. in diameter is designed for an internal pressure of 4 lbf/in.2 gauge in the vapor space. The plate material is ASTM A131 steel with appropriate grades for different plate thicknesses in accordance with Table 4-1 for a design metal temperature less than 65°F but not less than 25°F. No corrosion allowance is required for any portion of the tank. The top course of the butt-welded cylindrical sidewall is 1/4 in. thick. The roof is a single lap-welded spherical dome with an internal radius of 50 ft and a thickness of 1/4 in. The maximum design liquid level is 6 in. below the plane of the juncture of the tank API standard 650 flexible liquid storage tanks roof and sidewall.This specification, in conjunction with API 650 Standard, prescribes minimum standards for the API standard 650 flexible liquid storage tanks design, supply fabrication, erection, and testing of field erected welded steel storage tanks complete with accessories as specified herein and as shown on attached datasheets and/or drawings.We cooperated with the Peruvian government for many years. And supply them large diameter steel pipes and pipe fittings to support their Hydropower Station Projects. We do 100% UT, RT, Hydraulic test and so on tests for the API standard 650 flexible liquid storage tanks steel pipes. And do PT, MT and so on tests for the pipe fittings. We published "Welding Procedure Qualification report" after production. And our mill will keep the test record in the documentary department for 5 years. If meet any problems in following application, we can check the test record easily and assist to solve problems at the first time.The structure of the API standard 650 flexible liquid storage tanks foundation mainly includes the insulating anticorrosion layer on the top surface of the foundation, the tank wall support, the edge retaining structure, the sand cushion, the oil and water barrier, the detection signal tube and other structures. The construction materials and requirements of each basic structure of the storage tank are different. After the structure of the API standard 650 flexible liquid storage tanks foundation is built in accordance with the construction requirements, the settlement of the storage tank foundation needs to be observed, and the uneven settlement value of the storage tank foundation should be within the allowable safety range.The company attaches great importance to the cultivation of team spirit. Personal strength is weak. After sales service departments, leaders and subordinates often communicate with each other. Everyone often holds meetings to discuss their problems in after-sales service, discuss technical difficulties, discuss how to improve work efficiency, how to better deal with user complaints, etc.
Latest NewsMore+