CSA G40.21 Gr 44W plates API Std 650 anchored liquid-storage tanks
Our after sales department is an very important part of our department structures After the customer receive steel materials, our after sales department will follow up regularly and solve problems for them in time if they have the needs We romise to return the goods for free for its lifetime if it is quality of the steel material itself Meanwhile, if you have any advice or complaints, also welcome to feed back to our after sales department, and we are trying to give better service to you,API Std 650 anchored liquid-storage tanks. any joints between the adjacent sections of stiffening rings, as shown in Figure R-1, shall be made so that the required moment of inertia of the combined ring-shell section is provided. Weld joints between adjacent sections shall be made with full-thickness and full-penetration butt-welds. Stiffening-ring butt-welds may employ metal backing strips. Backing strips and the associated welding shall be made in a manner that provides a smooth contour in the rat hole and all other weld joints ends. All weld passes shall be started at the rat hole.Welding certification is regulated by Section 10 of the American Society of Mechanical Engineers (ASME). For both API Std 650 anchored liquid-storage tanks storage tank API 650, non-destructive inspection is required, but third-party inspection is not required.Based on the principle of “sincerity and win-win cooperation”, our company keeps forging ahead. In the fierce market competition, we have won the trust and rapid development of our customers with good cooperation and sincere service spirit. With pioneering spirit, the pursuit of excellence, continuous learning, and never satisfied content, we will create a win-win situation with our customers to create a better future. The company has sufficient inventory and complete varieties and specifications.Oil storage tank with floating roof structure: The floating roof in the API Std 650 anchored liquid-storage tanks oil storage tank can effectively reduce the volatilization consumption of oil, because the gas space on the oil liquid surface in the floating roof storage tank is small, the exhaust volume is low, and the breathing loss is very small. That can reduce the volatilization loss caused by the "big breath" of the API Std 650 anchored liquid-storage tanks. Strengthen the inspection and maintenance of API Std 650 anchored liquid-storage tanks: regularly check the sealing conditions of oil storage tanks, and check and maintain important auxiliary equipment to ensure good sealing performance.
Latest NewsMore+