CSA G40.21 Gr 44W plates API standard 650 anchored tanks
In cylindrical tank walls, the longitudinal weld joints in adjacent shell courses, including compression ring welds, shall be offset from each other a minimum distance of 12 in. The butt-weld around the periphery of a thickened insert plate, or the fillet weld around the periphery of a reinforcing plate, shall be at least the greater of 10 times the shell thickness or 12 in. from any butt-welded seam or the bottom-to-shell or roof-to-shell joint. As an alternative, the insert plate (or the API standard 650 anchored tanks reinforcing plate in an assembly that does not require stress relief) may extend to and intersect a flat-bottom-to-shell corner joint at approximately 90 degrees.
The thickness of the overburden on the top of the API 650 oil tank should not be less than 0.5m. The surrounding backfill with clean sand or fine soil should be no less than 0.3m thick; the API 650 oil tank API standard 650 anchored tanks operation platform ladder selection unit is considered in a unified manner. The buried operation well is designed for buried horizontal oil tanks, and the two are compatible.
In 2013, one of our clients in Korea purchased 890 tons Q345B square tube from us for one building construction project. Our clients required no burr in the side of the tube, we finally produce the goods with great condition and +/-0.25mm tolerance for wall thickness, which is a very great tolerance with customers’ required size. Our square tube full available range is 2-16mm for wall thickness, and 40-500mm for width. In addition, our Q/C department will seriously control all of the process of every order.
}Natural ventilation loss: the main cause of natural ventilation loss is that the API standard 650 anchored tanks is not tightly sealed. This is usually due to corrosion perforation on the top of the oil tank, or there is a height difference between the two orifices. The air tightness of the mixture in the API standard 650 anchored tanks is higher than that of the air, which causes the mixture gas in the tank to be discharged into the atmosphere from the lower hole, and the external air flows into the tank from the high hole, resulting in natural ventilation loss.
First of all, we should establish a correct concept of after-sales service. Service concept is an important part of corporate culture and a long-term enterprise value concept. Our company's after-sales service embodies the concept of "customer first, sincere service for customers". As long as we are in the "sincere service for users" under the guidance of the idea, I believe we will get rich returns.