API Std 650 SUG III tanks fabrication

API Standard 620 tank Appendix C describes the factors involved in obtaining adequate foundations for tanks that operate at atmospheric temperature. The foundations for refrigerated tanks are complicated because of the thermal movement of the tank, the insulation required for the bottom, the effects of foundation freezing and possible frost heaving, and the anchorage required to resist uplift. The services of a qualified foundation engineer are essential. Experience with tanks in the area may provide sufficient data, but normally a thorough investigation, including soil tests, would be required for proper design of the foundation.

This specification, in conjunction with API 650 Standard, prescribes minimum standards for the API Std 650 SUG III tanks design, supply fabrication, erection, and testing of field erected welded steel storage tanks complete with accessories as specified herein and as shown on attached datasheets and/or drawings.

The Seamless Pipe Q345D to Thailand. In November of 2015, Thailand OTTO group contacted with us from Internet. They are finding the trustable supplier of S355/2H seamless pipe for the cable car supporter. Due to the special using of the pipes, they are very careful and serious when choosing the supplier. After one months contact and discussion by email, they come to our company. We drive to the pipe mill for visit of 2 days. Through this visit, they are very confident with our production ability and products quality. Finally, they accept the grade we suggest Q345D. After back to office, they put the order of 1800 tons pipe to us directly.

}

API Std 650 SUG III tanks Manhole: The manhole is used for the operator to enter and exit the oil tank for inspection, cleaning and repair. For the convenience of personnel access, the installation position of the manhole is generally on the center line of the oil tank bottom, and the vertical oil tank is installed at the lowest layer of the tank wall. API Std 650 SUG III tanks Light-transmitting hole: Light-transmitting hole is also called day-lighting hole. It is used for lighting and ventilation when inspecting, repairing and scrubbing the oil tank. It is generally installed on the top of the oil tank above the inlet and outlet pipes.

Responsibilities: dealing with quality feedback and complaints from Customer.Bebon has the after sale service department, which is responsible to solve the problem of technical support and quality, service complaints. You can also contact the company customers service online if you have any problem when you receive the products. The responsibility is to deal with quality feedback and complaints from Customer. Welcome to come and visit our company office.