API Std 650 floating-roof tanks pontoon design

Design of a Double-wall Tank
The outer bottom, shell, and roof of a double-wall tank shall enclose an insulating space around the bottom, shell, and roof or insulation deck of the inner tank that contains the stored liquid. The annular space shall be maintained at a low positive pressure, which necessitates that the enclosure be vapor-tight. The Purchaser shall specify the design metal temperature and pressure of the inner tank and may specify the design temperature and pressure of the outer tank API Std 650 floating-roof tanks. The Purchaser shall state the specific gravity of the content to be stored, roof live loads, wind load, earthquake load where applicable, and corrosion allowance, if any.

Before the start of erection, inspect each API 650 tank foundation to ensure that it is level and acceptable to receive Work. Remove temporary erection attachments welded to the interior or exterior of the API Std 650 floating-roof tanks shell or to the bottom by arc gouging, and grind weld area smooth.

A Uganda client purchased 2100 tons SG255 gas cylinder steel coils in 2018. It is the first company in Uganda to provide re-furbishing, re-certification and manufacturing of new lpg cylinders. They have regular demands for sg255 coils API Std 650 floating-roof tanks every 3 months. Limited by inland location, we can only ship container to mombasa, and then transfer to kampala. OurJISG3116 SG255 steel product is grade for gas cylinder steel with the tensile strength of 400MPa and the yield strength of 255MPa.

}

Natural ventilation loss: the main cause of natural ventilation loss is that the API Std 650 floating-roof tanks is not tightly sealed. This is usually due to corrosion perforation on the top of the oil tank, or there is a height difference between the two orifices. The air tightness of the mixture in the API Std 650 floating-roof tanks is higher than that of the air, which causes the mixture gas in the tank to be discharged into the atmosphere from the lower hole, and the external air flows into the tank from the high hole, resulting in natural ventilation loss.

Through the operation and management, brand advantage and improve pre-sales, sale of after-sales service, the efforts of the company into the industry leading enterprises.Relying on perfect quality management system, it has built up competition predominance and provided high quality, favorable price and perfect after service for customers.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!