API 650 floating-roof tanks maximum design temperature

API 620 Crude Oil Tank Non-pressure Parts
Welds for pads, lifting lugs, and other nonpressure parts, as well as temporary lugs for alignment and scaffolding attached to primary components, shall be made in full compliance with a welding procedure qualified in accordance with Q.6.1. Lugs attached for erection purposes shall be removed, and any significant projections of API 650 floating-roof tanks weld metal shall be ground to a smooth contour. Plate that is gouged or torn in removing the lugs shall be repaired using a qualified procedure and then ground to a smooth contour. Where such repairs are made in primary components, the area shall be inspected by the liquid-penetrant method. A visual inspection is adequate for repairs in secondary components.

The API 650 is widely used for tanks designed to withstand low internal pressures, for the API 650 floating-roof tanks storage of typical products such as crude oil, petrol, chemicals and water. We have extensive experience when it comes to API 650 tanks, varying from tanks built in the factory up to +/- 500m3, to tanks built on-location up to +/-15,000 m3.

In 2016. Our company offer 1200 tons API 5L GR.B hot rolled coil to Bangladesh——100 tons for 3.9*625mm, and 1100 tons for 7*683mm. It is one tender project, we get the tender at the end of 2015, and arrange the production in 2016. They required the tolerance of thickness is +0.1/-0.2mm, and width tolerance is +/-0.5mm, which is a very high requirement for coil tolerance, but our mill handling this very well. and our Q/C department witness all of the process.

}

Static storage loss is also known as "small breathing" consumption. The rise and fall of the temperature in the API 650 floating-roof tanks leads to the increase and decrease of the pressure in the tank, which makes the mixed oil gas discharged from the tank, and the external air is sucked into the tank, resulting in the oil consumption. Fluid level loss is also called "big breathing" loss. It is the oil consumption caused by the change of gas space volume in the API 650 floating-roof tanks during the oil receiving and sending operation, which causes the mixed oil gas to be discharged out of the tank, and the external air is sucked into the tank, resulting in the oil consumption due to the change of liquid level height.

If customers have any difficult problems during use of the steel materials, they can contact the company's after-sales service department to feedback the existing problems. The after-sales department will reply as soon as possible to ensure that each customer has a good after-sales experience. Under special circumstances, the after-sales service department will start the problem-solving process, and the engineers in charge of the area will quickly follow up to solve the problem.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.