A516 Gr 55 plates API Std 650 aboveground oil storage tanks

The thickness of the API Std 650 aboveground oil storage tanks annular bottom plates shall be in accordance with Table Q-4 (for steel or aluminum, as applicable). The thicknesses shown are minimums. The ring of annual plates shall have a circular outside circumference, but it may have a regular polygonal shape inside the tank shell with the number of sides equal to the number of annular plates. These pieces shall be butt-welded in accordance with Q.7.1.1, Item b. The plates of the first shell course shall be attached to the annular bottom plates by a weld as required by API 620 oil tank 5.9.5 except when a full-penetration weld is used or required (see Q.7.1.1). Butt-welds in annular plates shall be not closer than 12 in. from any vertical weld.

API 650 Tanks in which liquid fluids are stored and designed to withstand atmospheric pressure operation, less than 18 kPa, or internal pressures not exceeding the weight of the API Std 650 aboveground oil storage tanks roof, with temperatures no higher than 93, 3 C are included in the scope of this design code.

our company offered 2950 ton A36 steel API Std 650 aboveground oil storage tanks plate to Philippines customer, which was used to build water supply project. It is the government project. The procurement with their project engineer come to China to discuss this project in middle of 2016. After checking the mill, they signed the contract with us. we supply the ASTM A36 Original Mill Test Certificate Stamped.

}

In the event of continuous heavy rainfall, the inspection of the API Std 650 aboveground oil storage tanks farm should be strengthened to monitor and pay close attention to the soil moisture content of the tank farm in order to quickly take emergency measures. Check whether the seals of the oil unloading port and the oil measuring port are in good condition in time to prevent rainwater from leaking into the API Std 650 aboveground oil storage tanks from the oil unloading port and the oil measuring port, which will affect the oil quality.

We should focus on the main problems to be solved and pay attention to efficiency. After receiving the user's quality objection report data, the possible causes, responsible units, compensation amount, etc. of the problem shall be judged based on experience. To have a clear service plan, to be clear about what your main problem is, what technical support is needed, these should be prepared.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!