Sliding friction resistance of API Std 650 storage tanks

The foundation design of the API Std 650 storage tanks should meet the requirements of foundation stability and deformation, that is, the API Std 650 storage tanks foundation should not be crushed and the uneven settlement value of the foundation should be within the allowable range. The uneven settlement of the storage tank foundation should be specified in the design process of the safe allowable range, because excessive uneven settlement will reduce the safety of the API Std 650 storage tanks and cause distortion and deformation of the tank wall and bottom plate.

The pressed-steel, round manhole with a 20-in. inside diameter shown in Figure F-8 is located in API 620 crude oil tank solid plate in spherical portion of a torispherical roof on a cylindrical storage tank 72 ft in diameter. The internal pressure, Pg, on the underside of the roof is 15 lbf/in.2 gauge. The thickness, t, of the roof plate required by 5.10.3 for the spherical portion of the roof is 1/2 in., which is exactly the thickness provided. No corrosion allowance is required. The materials in the oil tank roof plates and manhole frame conform to ASTM A283 Grade C steel; the main joints in the roof are double-welded butt joints, spot radiographed in accordance with 7.16 and 7.17.

The business department is mainly responsible for communicating with customers, from the manufacturing of steel plates, steel pipes and other products, knowing customers' needs and processing conditions, etc. within the time agreed with customers, the delivery time is short, the price is the most competitive, and the service is the best. Their responsibilities are to deal with customer consultation, solve customer problems, update production plans, and instruct the logistics department to deliver products to customers.

The outer FRP of API 650 oil tank will not produce electrolytic corrosion with groundwater and brine. The outer FRP will not corrode with gasoline, diesel oil and leaded gasoline API Std 650 storage tanks. The leakage detector can monitor the whole process 24 hours to eliminate the potential pollution. The leakage detection system is convenient for the inspection and maintenance of API 650 oil tank, and protects the original ecological environment of soil and groundwater.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]

Send a Message!