single-deck pontoon-type floating roof API Std 650 open top welded storage tanks
There is no dome roof in the top of the vertical external floating roof oil storage tank, only the disc floating roof which can float up and down. The wall plates are connected by butt welding, and the construction is usually carried out by the forward installation method, and the storage capacity is usually more than 10000 cubic meters. Vertical internal floating roof API Std 650 open top welded storage tanks has both dome roof and internal floating roof. The internal floating roof floats on the liquid surface inside the dome roof oil tank and can float up and down. The storage capacity is usually between 1000 and 10000 cubic meters.
The thickness of the API Std 650 open top welded storage tanks annular bottom plates shall be in accordance with Table Q-4 (for steel or aluminum, as applicable). The thicknesses shown are minimums. The ring of annual plates shall have a circular outside circumference, but it may have a regular polygonal shape inside the tank shell with the number of sides equal to the number of annular plates. These pieces shall be butt-welded in accordance with Q.7.1.1, Item b. The plates of the first shell course shall be attached to the annular bottom plates by a weld as required by API 620 oil tank 5.9.5 except when a full-penetration weld is used or required (see Q.7.1.1). Butt-welds in annular plates shall be not closer than 12 in. from any vertical weld.
In 2019, through the concerted cooperation of the enterprise team, the sales volume has grown steadily, and the annual sales volume has exceeded 300 million yuan. For this reason, both the investors and employees of the enterprise have received satisfactory returns. With strong development potential and brand advantages, we have always been committed to "integrity, efficiency, pragmatism, dedication" corporate spirit, dedication to society, and return to the public. From this perspective, the enterprise will have a bright future. In a good environment with strong hardware facilities and excellent management personnel, we can make sure that the company will develop stronger and bigger.
The tank wall design of API 650 oil storage tank. Since there is no ventilation pipe directly connected with the outside on the top of the API Std 650 open top welded storage tanks tank, the ventilation between the inside and outside of API 650 oil storage tank is realized by the respiration valve. The constant pressure of the respiration valve is 0.3kPa, so the pressure on the top of the tank is 0.3kPa.