Shop-assembled API Std 650 liquid storage tanks

Lateral braces between outer bay rafters must be provided if asymmetrical structural shapes are used for rafters and if the API Std 650 liquid storage tanks API 650 tanks are located in areas subject to earthquakes. The bracing must be adequately sized for the seismic zone specified.

The bottom plate of the vertical API Std 650 liquid storage tanks directly contacts with the foundation soil, which is suitable for the flexible foundation, and its settlement characteristics are quite different from that of the rigid foundation. For the settlement calculation of the foundation of a vertical API Std 650 liquid storage tanks, the one-way compression layered sum method can be used. The calculation method is to divide the foundation soil into several layers of compression within the calculation depth of the foundation settlement, and then find the sum. The calculation method of the compression amount of each layer is the same as the calculation method of the compression amount under the condition of no lateral deformation.

API Std 650 liquid storage tanks Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.

Customer service center has provided after-sales service for many large-scale information systems, and has accumulated rich working experience in the process of API Std 650 liquid storage tanks service for many years. It can provide accurate, timely and high-quality support and service for users, which is well received by users.

The trend of international shipping development of large-scale ships and strategic joint ventures puts forward higher requirements for modern ports. Modern ports no longer use the general cargo throughput as a measure sign, and container throughput will become the main sign to measure the role and status of modern ports. The average container capacity in 2000 is 3200teu, and it is expected to be 5500teu in 2020.

Have a question? Get a Free Consultation

If you are interested in our storage tanks, you can get contact with us through online consulting, demand table submission, e-mails and telephones.

Corporate Office

High-Tech Development Zone, Zhengzhou, China

Contact us

+86-371-86151527
[email protected]