Erection of API standard 650 cylindrical liquid-storage tank

API standard 650 cylindrical liquid-storage tank Liquid Relief ValvesA tank, which is likely to operate completely filled with liquid, shall be equipped with one or more liquid relief valves at the top of the roof, unless otherwise protected against overpressure. When such valves are, in effect, supplementary relief devices, they may be set at a pressure not greater than 1.25 times the design pressure. Because the relief valve at the pump, which provides the inflow of liquid to the tank, is set at a pressure greater than 1.25 times the design pressure of any tank that may be built under these rules, provision should be made for preventing overfilling of the tank by a self-closing float valve, by some practicable pilot-valve control, or by any other proven device.

The liquid level of API 650 oil storage tank is covered by floating roof. The storage liquid of API 650 oil storage API standard 650 cylindrical liquid-storage tank tank is isolated from the air, reducing air pollution, fire and explosion hazards, and easy to ensure the quality of liquid storage. It is especially suitable for the API standard 650 cylindrical liquid-storage tank storage of high-grade gasoline, jet fuel and toxic and easily polluted liquid chemicals.

This customer is a leading Engineering, Procurement and Construction company serving the Hydrocarbon and Chemical industries spanning Oil & Gas, Petrochemical, Refining, Fertilizer and related sectors in India. The A335 Grade P5 Steel Pipe and P9 API standard 650 cylindrical liquid-storage tank Seamless Steel Pipe we supplied is for EIL refineries project.

}

There is no dome roof in the top of the vertical external floating roof oil storage tank, only the disc floating roof which can float up and down. The wall plates are connected by butt welding, and the construction is usually carried out by the forward installation method, and the storage capacity is usually more than 10000 cubic meters. Vertical internal floating roof API standard 650 cylindrical liquid-storage tank has both dome roof and internal floating roof. The internal floating roof floats on the liquid surface inside the dome roof oil tank and can float up and down. The storage capacity is usually between 1000 and 10000 cubic meters.

After the order is finished, our after-sales service center will send an email to make a feedback about our steel products' quality. We have phone service every three months to remind our customers of the possible problems and collect advices or suggestions in quality and service. Upon the collection of advices or suggestions, our after-sales service will quickly make technical solutions to wipe out the customer problem.