EN S355J2 plates API Std 650 aboveground oil storage tanks

Corrosion allowance, if specified, shall be added to calculated API 650 tanks shell and self-supporting roof thicknesses; to minimum nominal thicknesses of bottom and supported API Std 650 aboveground oil storage tanks roof plates; to nozzles and manholes; and to all exposed surfaces of internal structural members and non-removable internals.

After years of operation and accumulation, the company has formed an operation network covering major economic cities across the country, with a group of high-quality professional logistics technicians and management personnel, strong strength and stable logistics channels. The company's business operations include the loading and unloading of steel raw materials and finished materials, API Std 650 aboveground oil storage tanks warehousing, and freight transportation. Our logistics service business has passenger transportation, automobile and construction machinery inspection, logistics information management and operations.

In this project, the area of tank wall used is of the same construction, material, and geometry as that described in F.1.3.1 except that the thickness of the plate is 3/8 in. The wall is stressed in the same manner as is described in F.1.3.1. A corrosion allowance of 1/16 in. is required. The computed (meridional) tensile stress, stc, in the net thickness after deduction of the corrosion allowance is 8000 lbf/in.2.
The problem in this example is to find the maximum allowable (latitudinal) compressive stress value for the given conditions, in conformance with the provisions of API 620 tank standard 5.5.4.5.
Solution: As determined from Table 5-1, the maximum allowable tensile stress value, Sts, for ASTM A285, Grade C, steel plate in simple tension is 16,500 lbf/in.2. Since the compressive stress is latitudinal, the governing value of R in this situation is R1, or 75 in.

The structure of the API Std 650 aboveground oil storage tanks foundation mainly includes the insulating anticorrosion layer on the top surface of the foundation, the tank wall support, the edge retaining structure, the sand cushion, the oil and water barrier, the detection signal tube and other structures. The construction materials and requirements of each basic structure of the storage tank are different. After the structure of the API Std 650 aboveground oil storage tanks foundation is built in accordance with the construction requirements, the settlement of the storage tank foundation needs to be observed, and the uneven settlement value of the storage tank foundation should be within the allowable safety range.