double-deck-type floating roof API standard 650 aboveground welded storage tanks
The quality inspection department is responsible for the inspection management of raw materials and finished products, and the quality inspection and acceptance of products and raw materials. Strictly abide by the company's management system, conscientiously exercise the management power given by the company, and put an end to all ultra vires; be responsible for the inspection of all kinds of raw materials entering the company, and put forward quality problems and handling opinions.
API standard 650 aboveground welded storage tanks Breathing valve: The function of the oil tank breathing valve is to adjust the oil and gas pressure in the tank. When the pressure in the tank is too high, part of the excess oil and gas will be discharged through the breathing valve to reduce the pressure in the tank; when the pressure in the tank is too low, through breathing The valve sucks in air from the outside of the tank to increase the pressure in the tank and keep it constant with the atmospheric pressure. The breathing valve is usually installed at the top of the oil tank.
All welded seams in the API standard 650 aboveground welded storage tanks bottom, and complete penetration and complete fusion sidewall-to-bottom welds, shall be inspected by means of a vacuum box test as described in Q.8.2.1. Sidewall-to-bottom welds not having complete penetration and complete fusion shall be inspected by means of either a vacuum box test of the inside weld as described in API 620 specification Q.8.2.1, or where approved by the Purchaser, a direct pressure solution film test as described in Q.8.2.2.