CSA G40.21 grade 44W plates API Std 650 unanchored tanks
Data Required from Manufacturer on Completed TanksIf specified in the purchase order, the Manufacturer shall supply marked copies of plans (or a separate sketch) showing the location of all plates, with a means of identifying each plate with the heat numbers. These markings shall be checked by the inspector. A copy shall be attached to the Manufacturer’s report.Check of Stress-relieving OperationThe API Std 650 unanchored tanks inspector shall check any thermal stress-relieving operation and shall be satisfied that the temperature readings are accurate and that the procedure conforms to the applicable requirements of these rules.
Similarities between API 650 and API 620 tanks Both tanks are used for storage purposes. Both API 620 and API 650 containers API Std 650 unanchored tanks can be made of carbon steel, austenitic stainless steel and nickel alloy (only for low temperature).
API Std 650 unanchored tanks, Vertical oil storage tank is an important equipment for many enterprises to carry out production, which provides important support and help for the storage of many reagents. Vertical storage tank is generally used as atmospheric pressure vessel. Advantages: the filling rate of cylindrical structure is second to that of spherical tank, and the largest volume of the storage tank can be made into tens of thousands of cubic meters. The structure is simple and the construction requirements are relatively low.